-- AT-LOG.MIB, Allied Telesis enterprise MIB:
-- Log MIB for the AlliedWare Plus(tm) operating system
--
-- Copyright (c) 2011 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================

    AT-LOG-MIB DEFINITIONS ::= BEGIN

        IMPORTS
            modules
                FROM AT-SMI-MIB
            Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
                FROM SNMPv2-SMI
            DisplayString
                FROM SNMPv2-TC;


        log MODULE-IDENTITY
            LAST-UPDATED "201606230000Z"
            ORGANIZATION
                "Allied Telesis Labs New Zealand"
            CONTACT-INFO
                "http://www.alliedtelesis.com"
            DESCRIPTION
                "Added logProcessKilledNotify and MIB variable logProcessKilled."
            REVISION "201606230000Z"
            DESCRIPTION
                "The AT Log MIB, for listing log entries from the buffered and permament logs."
            REVISION "201206080000Z"
            DESCRIPTION
                "Change OCTET STRING to DisplayString for all MIBs."
            REVISION "201206070000Z"
            DESCRIPTION
                "Change the MAX-ACCESS for the logIndex to not-accessible."
            REVISION "201105300000Z"
            DESCRIPTION
                "Updated enumeration type to use INTEGER."
            REVISION "201104180000Z"
            DESCRIPTION
                "Reformatted MIB file."
            REVISION "201009070000Z"
            DESCRIPTION
                "Generic syntax tidy up"
            REVISION "201006140511Z"
            DESCRIPTION
                "MIB revision history dates in descriptions updated."
            REVISION "200810080000Z"
            DESCRIPTION
                "Initial revision."
            ::= { modules 601 }



--
-- Node definitions
--

        logNotifications OBJECT IDENTIFIER ::= { log 0 }


        logProcessKilledNotify NOTIFICATION-TYPE
            OBJECTS { logProcessKilled }
            STATUS current
            DESCRIPTION
                "A notification is generated when a process is killed."
            ::= { logNotifications 1 }

-- ---------------------------------------------------------- --
-- The log table
-- ---------------------------------------------------------- --
        logTable OBJECT-TYPE
            SYNTAX SEQUENCE OF LogEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "A list of log entries from the source specified in the
                logSource object. The list is ordered from oldest entry to
                newest entry."
            ::= { log 1 }


        logEntry OBJECT-TYPE
            SYNTAX LogEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "A log entry from the source specified in the logSource object."
            INDEX { logIndex }
            ::= { logTable 1 }


        LogEntry ::=
            SEQUENCE {
                logIndex
                    Unsigned32,
                logDate
                    DisplayString,
                logTime
                    DisplayString,
                logFacility
                    DisplayString,
                logSeverity
                    DisplayString,
                logProgram
                    DisplayString,
                logMessage
                    DisplayString
             }

        logIndex OBJECT-TYPE
            SYNTAX Unsigned32
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "An index value. This index is not directly tied to any
                specific log entry. Over time, the log will grow larger and
                eventually older entries will be removed."
            ::= { logEntry 1 }


        logDate OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The date that the log was generated, in the form YYYY MMM DD,
                eg: 2008 Oct  9."
            ::= { logEntry 2 }


        logTime OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The time that the log was generated, in the form HH:MM:SS,
                eg: 07:15:04."
            ::= { logEntry 3 }


        logFacility OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The syslog facility that generated the log entry. See the
                Software Reference Manual for more information."
            ::= { logEntry 4 }


        logSeverity OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The severity level of the log entry:

                  emerg     Emergency, system is unusable
                  alert     Action must be taken immediately
                  crit      Critical conditions
                  err       Error conditions
                  warning   Warning conditions
                  notice    Normal, but significant, conditions
                  info      Informational messages
                  debug     Debug-level messages"
            ::= { logEntry 5 }


        logProgram OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The program that generated the log entry. See the Software
                Reference Manual for more information."
            ::= { logEntry 6 }


        logMessage OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The log message."
            ::= { logEntry 7 }


-- ---------------------------------------------------------- --
-- The log options
-- ---------------------------------------------------------- --
        logOptions OBJECT IDENTIFIER ::= { log 2 }


        logSource OBJECT-TYPE
            SYNTAX INTEGER
            {
            	bufferedLog(1),
            	permanentLog(2)
            }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The source to retrieve the log entries from. Valid values are:

                  1 - Buffered log
                  2 - Permanent log

                This source is used when retrieving the logTable objects, and
                also specifies the log to be cleared when the clearLog object
                is set."
            ::= { logOptions 1 }


        logAll OBJECT-TYPE
            SYNTAX Integer32 (0..1)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Determines the quantity of logs to be retrieved. Valid values
                are:

                  0 - Display only recent log messages
                  1 - Show all available log entries.

                Note: Choosing to retrieve all log entries may result in a
                delay of several seconds before they may be viewed via SNMP."
            ::= { logOptions 2 }


        clearLog OBJECT-TYPE
            SYNTAX Integer32 (0..1)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Set with a value of 1 to clear the log that is specified by
                the logSource object."
            ::= { logOptions 3 }

-- ---------------------------------------------------------- --
-- The date and time when syslog-ng was restarted
-- ---------------------------------------------------------- --

        logProcessKilled OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The process name that a process daemon was killed. This MIB variable is a
                placeholder for the logProcessKilledNotify, but can be read independently if required.
                A new process killed event can update this variable. No message will be displayed if
                the specified process has not been killed after the device was first booted."
            ::= { log 3 }


    END

--
-- at-log.mib
--