-- Copyright (c) 2004-2015 Hangzhou H3C Tech. Co., Ltd.  All rights reserved.
--
-- Description: description of entity extend properties.
-- Reference:
-- History V3.2
-- V1.0 Created by weixinzhe, Thursday, April 22, 2004 at 18:26:02
-- V1.1 modified by yelinhui, add hh3cEntityExtMacAddress
-- V1.2 modified by panxidong, add hh3cEntityExtErrorStatus
-- V1.3 2004-10-12 updated by gaolong
--      Remove BITS from IMPORTS
-- V1.4 2005-02-25 modified by longyin
--      Add error status stackPortBlocked(22) and stackPortFailed(23)
--      for hh3cEntityExtErrorStatus
-- V1.5 2006-05-16 modified by wangsihai
--      Add error status sensorError(81) in hh3cEntityExtErrorStatus
-- V1.6 2006-07-03 modified by lifengguang
--      Add hh3cEntityExtManuTable
-- V1.7 2007-09-21 modified by lifengguang
--      Add notification object hh3cEntityExtSFPAlarmOn and hh3cEntityExtSFPAlarmOff
--      Add hh3cEntityExtPowerTable
-- V1.8 2007-11-19 modified by jinyi
--      Add hh3cEntityExtCpuMaxUsage
-- V1.9 2008-02-27 modified by lifengguang
--      Add Trap nodes: hh3cEntityExtSFPPhony
-- V2.0 2008-07-11 modified by lisong
--      Add hh3cProcessTable
--      Add notification object hh3cEntityInsert and hh3cEntityRemove
-- V2.1 2008-07-14 modified by lifengguang
--      Add error status hardwareFaulty(91) in hh3cEntityExtErrorStatus
--      Add Trap nodes: hh3cEntityExtForcedPowerOff and hh3cEntityExtForcedPowerOn
--      Add Trap nodes: hh3cEntityExtFaultAlarmOn and hh3cEntityExtFaultAlarmOff
-- V2.2 2008-10-24 modified by lifengguang
--      Add nodes hh3cEntityExtLowerTemperatureThreshold and
--      hh3cEntityExtShutdownTemperatureThreshold in hh3cEntityExtStateTable
--      Add trap nodes hh3cEntityExtResourceLack and hh3cEntityExtResourceEnough
--      in hh3cEntityExtTrapsPrefix
--      Add trap nodes hh3cEntityExtTemperatureLower, hh3cEntityExtTemperatureTooUp
--      and hh3cEntityExtTemperatureNormal in hh3cEntityExtTrapsPrefix
-- V2.3 2009-04-07 Added trap nodes hh3cEntityExternalAlarmOccur and
--      hh3cEntityExternalAlarmRecover
-- v2.4 2009-05-05 Added hh3cEntityExtCpuAvgUsage, hh3cEntityExtMemAvgUsage,
--      hh3cEntityExtPhyMemSize, hh3cEntityExtMemType, hh3cEntityExtPhyCpuFrequency,
--      hh3cEntityExtFirstUsedDate,
--      hh3cEntityExtCpuUsageThresholdRecover, hh3cEntityExtMemUsageThresholdRecover
-- V2.5 2010-08-09
--      Added hh3cEntityExtShutdownLowerTemperatureThreshold,
--      hh3cEntityExtCriticalLowerTemperatureThreshold,
--      hh3cEntityExtCritLowerTempThresholdNotification and
--      hh3cEntityExtTemperatureTooLow by zhanglei 06807.
--      Added hh3cEntityExtMemAllocatedFailed, hh3cEntityExtECCParityAlarm,
--      hh3cEntityExtTrapDescription, hh3cEntityExtECCParityAlarmStatus
--      by zhangqingjun 02357.
--      Modified description of hh3cEntityExtPhyMemSize by haoyan 06611.
-- V2.6 2010-12-06
--      Added hh3cEntityExtFanDirectionNotPreferred, hh3cEntityExtFanDirectionNotAccord
--      by lifengguang 03035.
-- V2.7 2011-04-06
--      Added hh3cEntityExtSFPInvalid, hh3cEntityExtSFPInvalidNow and
--      hh3cEntityExtSFPInvalidInDays by songhao 02718.
--      Changed SYNTAX of hh3cEntityExtMemSize and hh3cEntityExtPhyMemSize
--      from Integer32 to Unsigned32 by songhao 02718.
-- V2.8 2011-08-30
--      Added hh3cEntityExtCpuUsageRecoverThreshold;
--      Added hh3cEntityExtCpuUsageRecoverThreshold to hh3cEntityExtCpuUsageThresholdNotfication and
--      hh3cEntityExtCpuUsageThresholdRecover by shuaixiaojuan 04117.
--      Added hh3cEntityExtFirstTrapTime by duyanbing 04404.
-- V2.9 2013-04-27
--      Added hh3cEntityExtMemSizeRev by fangliwen 08502.
--      Added trap nodes hh3cEntityExtMemUsageThresholdOverTrap and
--      hh3cEntityExtMemUsageThresholdRecoverTrap by fangliwen 08502.
-- V3.0 2013-12-16
--      Added hh3cEntityExtCpuUsageIn1Minute and hh3cEntityExtCpuUsageIn5Minutes
--      by fangliwen 08502.
-- V3.1 2014-01-24
--      Added hh3cEntityExtVoltageObjects by fangliwen 08502.
--      Added trap nodes hh3cEntityExtVoltageNormal, hh3cEntityExtVoltageTooLow,
--      hh3cEntityExtVoltageLower, hh3cEntityExtVoltageHigher and
--      hh3cEntityExtVoltageTooHigh by fangliwen 08502.
-- V3.2 2015-01-12
--      Added trap nodes hh3cEntityExtSFPAlarmOnEx, hh3cEntityExtSFPAlarmOffEx by fangliwen 08502.
-- =================================================================
HH3C-ENTITY-EXT-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        hh3cCommon
            FROM HH3C-OID-MIB
        OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
            FROM SNMPv2-CONF
        OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32,
        Unsigned32, Gauge32, TimeTicks
            FROM SNMPv2-SMI
        TEXTUAL-CONVENTION, MacAddress, DateAndTime, DisplayString
            FROM SNMPv2-TC
        SnmpAdminString
            FROM SNMP-FRAMEWORK-MIB
        entPhysicalIndex, entPhysicalName, entPhysicalDescr
            FROM ENTITY-MIB
        CounterBasedGauge64
            FROM HCNUM-TC;

    hh3cEntityExtend MODULE-IDENTITY
        LAST-UPDATED "201501120000Z"
        ORGANIZATION
            "Hangzhou H3C Technologies Co., Ltd."
        CONTACT-INFO
            "Platform Team H3C Technologies Co., Ltd.
             Hai-Dian District Beijing P.R. China
             http://www.h3c.com
             Zip: 100085"
        DESCRIPTION
            "The private MIB file includes the general extent
            information of the device."
        ::= { hh3cCommon 6 }

    Hh3cAdminState  ::=  TEXTUAL-CONVENTION
        STATUS            current
        DESCRIPTION
            "The administrative state for this object, and it is possible to
            set the state when needed.
            A value of locked means the resource is administratively prohibited
            from use. A value of shuttingDown means that usage is
            administratively limited to current instances of use.
            A value of unlocked means the resource is not administratively
            prohibited from use."
        REFERENCE
            "ITU Recommendation X.731, 'Information Technology - Open
            Systems Interconnection - System Management: State
            Management Function', 1992"
        SYNTAX  INTEGER
        {
            notSupported(1),
            locked(2),
            shuttingDown(3),
            unlocked(4)
        }

    Hh3cOperState  ::=  TEXTUAL-CONVENTION
        STATUS            current
        DESCRIPTION
            " Represents the possible values of operational states.
            A value of disabled means the resource is totally
            inoperable. A value of enabled means the resource
            is partially or fully operable."
        REFERENCE
            "ITU Recommendation X.731, 'Information Technology - Open
            Systems Interconnection - System Management: State
            Management Function', 1992"
        SYNTAX  INTEGER
        {
            notSupported (1),
            disabled(2),
            enabled(3),
            dangerous(4)
        }
    Hh3cAlarmStatus  ::=  TEXTUAL-CONVENTION
        STATUS            current
        DESCRIPTION
            "Represents the possible values of alarm status.
            When no bits of this attribute are set, then none of the
            status conditions described below are present. When the
            value of under repair is set, the resource is currently
            being repaired.

            When the value of critical is set, one or more critical
            alarms are active against the resource. When the value of
            major is set, one or more major alarms are active against
            the resource. When the value of minor is set, one or more
            minor alarms are active against the resource. When the
            value of warning is set, one or more warning alarms are
            active against the resource. When the value of
            indeterminate is set, one or more  alarms of indeterminate
            severity are active against the resource.
            When the value of alarm outstanding is set, one or more
            alarms is active against the resource. The fault may or may
            not be disabling."
            REFERENCE
            "ITU Recommendation X.731, 'Information Technology - Open
            Systems Interconnection - System Management: State
            Management Function', 1992"
        SYNTAX           BITS
        {
            notSupported (0),
            underRepair(1),
            critical(2),
            major(3),
            minor(4),
            alarmOutstanding(5),
            warning (6), -- Not defined in X.731
            indeterminate (7) -- Not defined in X.731
        }


    Hh3cStandbyStatus  ::=  TEXTUAL-CONVENTION
        STATUS            current
        DESCRIPTION
                " Represents the possible values of standby status.

                  A value of hotStandby means the resource is not providing
                  service, but is will be immediately able to take over the
                  role of the resource to be backed-up, without the need for
                  initialization activity, and will contain the same
                  information as the resource to be backed up. A value of
                  coldStandy means that the resource is to back-up another
                  resource, but will not be immediately able to take over
                  the role of a resource to be backed up, and will require
                  some initialization activity. A value of providingService
                  means the resource is providing service."
        REFERENCE
            "ITU Recommendation X.731, 'Information Technology - Open
            Systems Interconnection - System Management: State
            Management Function', 1992"
        SYNTAX            INTEGER
        {
            notSupported (1),
            hotStandby(2),
            coldStandby(3),
            providingService(4)
        }


    hh3cEntityExtObjects OBJECT IDENTIFIER ::= { hh3cEntityExtend 1 }


--  MIB contains four groups

    hh3cEntityExtState OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 1 }

    hh3cEntityExtStateTable OBJECT-TYPE
        SYNTAX SEQUENCE OF Hh3cEntityExtStateEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "This table contains one row per physical entity, There is
            always at least one row for an 'overall' physical entity.
            The information in each row may be not include all the object
            in this table, because of the entity need not some of the
            information here."
        ::= { hh3cEntityExtState 1 }

    hh3cEntityExtStateEntry OBJECT-TYPE
        SYNTAX Hh3cEntityExtStateEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The information about a particular physical entity."
        INDEX { hh3cEntityExtPhysicalIndex }
        ::= { hh3cEntityExtStateTable 1 }

    Hh3cEntityExtStateEntry ::= SEQUENCE {
        hh3cEntityExtPhysicalIndex
            Integer32,
        hh3cEntityExtAdminStatus
            Hh3cAdminState,
        hh3cEntityExtOperStatus
            Hh3cOperState,
        hh3cEntityExtStandbyStatus
            Hh3cStandbyStatus,
        hh3cEntityExtAlarmLight
            Hh3cAlarmStatus,
        hh3cEntityExtCpuUsage
            Integer32,
        hh3cEntityExtCpuUsageThreshold
            Integer32,
        hh3cEntityExtMemUsage
            Integer32,
        hh3cEntityExtMemUsageThreshold
            Integer32,
        hh3cEntityExtMemSize
            Unsigned32,
        hh3cEntityExtUpTime
            Integer32,
        hh3cEntityExtTemperature
            Integer32,
        hh3cEntityExtTemperatureThreshold
            Integer32,
        hh3cEntityExtVoltage
            Integer32,
        hh3cEntityExtVoltageLowThreshold
            Integer32,
        hh3cEntityExtVoltageHighThreshold
            Integer32,
        hh3cEntityExtCriticalTemperatureThreshold
            Integer32,
        hh3cEntityExtMacAddress
            MacAddress,
        hh3cEntityExtErrorStatus
            INTEGER,
        hh3cEntityExtCpuMaxUsage
            Integer32,
        hh3cEntityExtLowerTemperatureThreshold
            Integer32,
        hh3cEntityExtShutdownTemperatureThreshold
            Integer32,
        hh3cEntityExtPhyMemSize
            Unsigned32,
        hh3cEntityExtPhyCpuFrequency
            Integer32,
        hh3cEntityExtFirstUsedDate
            DateAndTime,
        hh3cEntityExtCpuAvgUsage
            Integer32,
        hh3cEntityExtMemAvgUsage
            Integer32,
        hh3cEntityExtMemType
            OCTET STRING,
        hh3cEntityExtCriticalLowerTemperatureThreshold
            Integer32,
        hh3cEntityExtShutdownLowerTemperatureThreshold
            Integer32,
        hh3cEntityExtCpuUsageRecoverThreshold
            Integer32,
        hh3cEntityExtMemSizeRev
            CounterBasedGauge64,
        hh3cEntityExtCpuUsageIn1Minute
            Integer32,
        hh3cEntityExtCpuUsageIn5Minutes
            Integer32
     }

    hh3cEntityExtPhysicalIndex OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS accessible-for-notify
        STATUS current
        DESCRIPTION
            "The index of hh3cEntityExtStateTable.
            This index is identical to entPhysicalIndex in ENTITY-MIB"
        ::= { hh3cEntityExtStateEntry 1 }

    hh3cEntityExtAdminStatus OBJECT-TYPE
        SYNTAX Hh3cAdminState
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The administrative state for this object."
        ::= { hh3cEntityExtStateEntry 2 }

    hh3cEntityExtOperStatus OBJECT-TYPE
        SYNTAX Hh3cOperState
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The operate state for this object."
        ::= { hh3cEntityExtStateEntry 3 }

    hh3cEntityExtStandbyStatus OBJECT-TYPE
        SYNTAX Hh3cStandbyStatus
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "This object is used for monitoring standby status.
            Not all entities support this object."
        ::= { hh3cEntityExtStateEntry 4 }

    hh3cEntityExtAlarmLight OBJECT-TYPE
        SYNTAX Hh3cAlarmStatus
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The alarm status for this entity. It does not include
            the severity of alarms raised on child components. In
            this condition, there will be a alarm light on the entity,
            the object should have the same status with it."
        ::= { hh3cEntityExtStateEntry 5 }

    hh3cEntityExtCpuUsage OBJECT-TYPE
        SYNTAX Integer32 (0..100)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The CPU usage for this entity. Generally, the overall
            CPU usage on the entity is calculated, independent of
            the number of CPUs on the entity."
        ::= { hh3cEntityExtStateEntry 6 }

    hh3cEntityExtCpuUsageThreshold OBJECT-TYPE
        SYNTAX Integer32 (0..100)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The threshold for the CPU usage. When the CPU usage exceeds
            the threshold, a notification will be sent."
        ::= { hh3cEntityExtStateEntry 7 }

    hh3cEntityExtMemUsage OBJECT-TYPE
        SYNTAX Integer32 (0..100)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The memory usage for the entity. This object indicates what
            percent of memory are used."
        ::= { hh3cEntityExtStateEntry 8 }

    hh3cEntityExtMemUsageThreshold OBJECT-TYPE
        SYNTAX Integer32 (0..100)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The threshold for the Memory usage, When the memory usage
            exceeds the threshold, a notification will be sent."
        ::= { hh3cEntityExtStateEntry 9 }

    hh3cEntityExtMemSize OBJECT-TYPE
        SYNTAX Unsigned32
        UNITS "bytes"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The size of memory for the entity.

            If the amount of memory exceeds 4,294,967,295 bytes,
            the value remains 4,294,967,295 bytes."
        ::= { hh3cEntityExtStateEntry 10 }

    hh3cEntityExtUpTime OBJECT-TYPE
        SYNTAX Integer32
        UNITS "seconds"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The uptime for the entity. The meaning of uptime is
            when the entity is up, and the value of the object
            will add 1 seconds while the entity is running."
        ::= { hh3cEntityExtStateEntry 11 }

    hh3cEntityExtTemperature OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The temperature for the entity."
        ::= { hh3cEntityExtStateEntry 12 }

    hh3cEntityExtTemperatureThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The threshold for the temperature. When the temperature
            exceeds the threshold, a notification will be sent."
        ::= { hh3cEntityExtStateEntry 13 }

    hh3cEntityExtVoltage OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The voltage for the entity."
        ::= { hh3cEntityExtStateEntry 14 }

    hh3cEntityExtVoltageLowThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The low-threshold for the voltage.
            When voltage is lower than low-threshold, a notification will be
            sent."
        ::= { hh3cEntityExtStateEntry 15 }

    hh3cEntityExtVoltageHighThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The high-threshold for the voltage.
            When voltage greater than high-threshold, a notification will be
            sent."
        ::= { hh3cEntityExtStateEntry 16 }

    hh3cEntityExtCriticalTemperatureThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            " The threshold for the critical Temperature. When temperature
            exceeds the critical temperature, a notification will be sent."
        ::= { hh3cEntityExtStateEntry 17 }

    hh3cEntityExtMacAddress OBJECT-TYPE
        SYNTAX MacAddress
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "MAC Address of the entity."
        ::= { hh3cEntityExtStateEntry 18 }

    hh3cEntityExtErrorStatus OBJECT-TYPE
        SYNTAX INTEGER
            {
            notSupported(1),
            normal(2),
            postFailure(3),
            entityAbsent(4),
            poeError(11),
            stackError(21),
            stackPortBlocked(22),
            stackPortFailed(23),
            sfpRecvError(31),
            sfpSendError(32),
            sfpBothError(33),
            fanError (41),
            psuError(51),
            rpsError(61),
            moduleFaulty(71),
            sensorError(81),
            hardwareFaulty(91)
            }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Indicate the error state of this entity object. Now it only
            supports Port, general power supply, RPS power supply and
            board/Subcard. It may have one of these values.
            The following four values  can be used for all kinds of entities.

            notSupported(1) means this entity cannot support this function.
            normal(2) means the statement of this entity is normal. for ports,
            it doesn't differentiate 10M/s, 100M/s, 1000M/s, duplex and
            half-duplex. For fan, power supply and board-Subcard, it means
            their states are normal.
            postFailure(3)  means the entity fails to POST.
            entityAbsent(4) means the entity is absent now.


            The following values is depended on the entity.

            For Port entities, it may have the following  values. If its POST
            is failure,
            then the value of the instance will be postFailure(3), otherwise
            the value will be normal(2).

            If enable power supply over Ethernet on this port is failure,
            the value of this instance will be poeError(11), otherwise it will
            be normal(2).

            For stack port, if it connects to another stack port normally, and
            these two units merge into one stack, then the value of this
            instance will be normal(2).
            If something wrong occurs and the unit cannot merge into stack,
            the value of this instance will be stackPortFailed(23).  If the
            stack port forms resilient daisy chain with another stack port
            on the other unit, the value of this instance will be
            stackPortBlocked(22).


            For SFP ports, if it fail to receive, the value of this instance
            will be sfpRecvError(31), if it fail to send, the value is
            sfpSendError(32), if it fail to send and receive, the value is
            sfpBothError(33), otherwise it will be normal(2).

            fanError(41) means that the fan stops working.

            psuError(51) means that the Power Supply Unit is in the state of
            fault.

            rpsError(61) means the RPS is in the state of fault.

            moduleFaulty(71) means the Module is in the state of fault.

            sensorError(81) means the sensor is in the state of fault.

            hardwareFaulty(91) means the hardware of specified entity is in the state of fault.

            NMS must be compatible with the states which may be added
            in the future."
        ::= { hh3cEntityExtStateEntry 19 }

    hh3cEntityExtCpuMaxUsage OBJECT-TYPE
        SYNTAX Integer32(0..100)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The maximal CPU usage for the entity in the period of time."
        ::= { hh3cEntityExtStateEntry 20 }

    hh3cEntityExtLowerTemperatureThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The threshold for the lower Temperature. When temperature runs
            under the threshold, a notification will be sent."
        ::= { hh3cEntityExtStateEntry 21 }

    hh3cEntityExtShutdownTemperatureThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The threshold for the shutdown Temperature. When temperature
            exceeds the threshold, a notification will be sent and the entity
            will be shutdown."
        ::= { hh3cEntityExtStateEntry 22 }

    hh3cEntityExtPhyMemSize OBJECT-TYPE
        SYNTAX Unsigned32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The memory size of entity. This is the physical attribute of entity."
        ::= { hh3cEntityExtStateEntry 23 }

    hh3cEntityExtPhyCpuFrequency OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The CPU frequency of entity. Unit of measure is MHZ."
        ::= { hh3cEntityExtStateEntry 24 }

    hh3cEntityExtFirstUsedDate OBJECT-TYPE
        SYNTAX DateAndTime (SIZE(8))
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The first used date of the entity."
        ::= { hh3cEntityExtStateEntry 25 }

    hh3cEntityExtCpuAvgUsage OBJECT-TYPE
        SYNTAX Integer32(0..100)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The average CPU usage for the entity in a period of time."
        ::= { hh3cEntityExtStateEntry 26 }

    hh3cEntityExtMemAvgUsage OBJECT-TYPE
        SYNTAX Integer32(0..100)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The average memory usage for the entity in a period of time."
        ::= { hh3cEntityExtStateEntry 27 }

    hh3cEntityExtMemType OBJECT-TYPE
        SYNTAX OCTET STRING(SIZE (0..64))
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The memory type of entity."
        ::= { hh3cEntityExtStateEntry 28 }

    hh3cEntityExtCriticalLowerTemperatureThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The threshold for the critical Temperature.  When temperature
            exceeds the critical lower temperature, a notification will be sent."
        ::= { hh3cEntityExtStateEntry 29 }

    hh3cEntityExtShutdownLowerTemperatureThreshold OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The threshold for the shutdown Temperature.  When temperature
            exceeds the lower threshold, a notification will be sent and the entity
            will be shutdown."
        ::= { hh3cEntityExtStateEntry 30 }

    hh3cEntityExtCpuUsageRecoverThreshold OBJECT-TYPE
        SYNTAX Integer32 (0..100)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The recover threshold for the CPU usage.  When the CPU usage falls down to
            the threshold, a notification is sent.  The hh3cEntityExtCpuUsageRecoverThreshold
            must be less than or equal to the hh3cEntityExtCpuUsageThreshold."
        DEFVAL      { 100 }
        ::= { hh3cEntityExtStateEntry 31 }

    hh3cEntityExtMemSizeRev OBJECT-TYPE
        SYNTAX CounterBasedGauge64
        UNITS "bytes"
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Size of memory space for the entity.

            This node is used to replace hh3cEntityExtMemSize."
        ::= { hh3cEntityExtStateEntry 32 }

    hh3cEntityExtCpuUsageIn1Minute OBJECT-TYPE
        SYNTAX Integer32 (0..100)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The CPU usage in last one minute for this entity.
            Generally, the overall CPU usage on the entity is
            calculated, independent of the number of CPUs on
            the entity."
        ::= { hh3cEntityExtStateEntry 33 }

    hh3cEntityExtCpuUsageIn5Minutes OBJECT-TYPE
        SYNTAX Integer32 (0..100)
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The CPU usage in last five minutes for this entity.
            Generally, the overall CPU usage on the entity is
            calculated, independent of the number of CPUs on
            the entity."
        ::= { hh3cEntityExtStateEntry 34 }

    hh3cEntityExtManu OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 2 }

    hh3cEntityExtManuTable OBJECT-TYPE
        SYNTAX SEQUENCE OF Hh3cEntityExtManuEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The table about device manufacture information."
        ::= { hh3cEntityExtManu 1 }

    hh3cEntityExtManuEntry OBJECT-TYPE
        SYNTAX Hh3cEntityExtManuEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The device manufacture information about a particular physical
            entity."
        INDEX { hh3cEntityExtManuPhysicalIndex }
        ::= { hh3cEntityExtManuTable 1 }

    Hh3cEntityExtManuEntry ::= SEQUENCE {
        hh3cEntityExtManuPhysicalIndex
            Integer32,
        hh3cEntityExtManuSerialNum
            SnmpAdminString,
        hh3cEntityExtManuBuildInfo
            SnmpAdminString,
        hh3cEntityExtManuBOM
            SnmpAdminString,
        hh3cEntityExtMacAddressCount
            Unsigned32
     }

    hh3cEntityExtManuPhysicalIndex OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        MAX-ACCESS accessible-for-notify
        STATUS current
        DESCRIPTION
            "The index of hh3cEntityExtManuTable.
            This index is identical to entPhysicalIndex in ENTITY-MIB."
        ::= { hh3cEntityExtManuEntry 1 }

    hh3cEntityExtManuSerialNum OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Manufacture serial number.
            The manufacture serial number of the entity such as chassis,
            module, and so on.  It is got from the device when manufacturing.
            For low level box-device, the manufacture serial number is the
            device-number of System Control Board(SCB for short), it is written
            into the SCB directly; for middle level or high level frame-device,
            the manufacture serial number is the device-numbers of SCB and
            Service Board, because the SCB, Service Board and chassis are
            separate to sale and the device-number of chassis cannot be
            written into board."
        ::= { hh3cEntityExtManuEntry 2 }

    hh3cEntityExtManuBuildInfo OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Device version information.
            The device version information of the entity such as chassis,
            module, and so on.  It consists of software version information
            and hardware version information."
        ::= { hh3cEntityExtManuEntry 3 }

    hh3cEntityExtManuBOM OBJECT-TYPE
        SYNTAX SnmpAdminString
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Device BOM code.
            The device BOM code of the entity such as chassis, module, and so
            on.  It is the component code of ERP system, which can be
            disassembled from device-number."
        ::= { hh3cEntityExtManuEntry 4 }

    hh3cEntityExtMacAddressCount OBJECT-TYPE
        SYNTAX Unsigned32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "MAC address count.
            The count of MAC addresses of the entity, such as chassis, module,
            or port, and so on."
        ::= { hh3cEntityExtManuEntry 5 }

    hh3cEntityExtPower OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 3 }

    hh3cEntityExtPowerTable OBJECT-TYPE
        SYNTAX SEQUENCE OF Hh3cEntityExtPowerEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "This table describes the power information of all the physical
            entity on the device, such as the fans, the subcards, the boards,
            etc."
        ::= { hh3cEntityExtPower 1 }

    hh3cEntityExtPowerEntry OBJECT-TYPE
        SYNTAX Hh3cEntityExtPowerEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The entity power information about a particular physical entity."
        INDEX { hh3cEntityExtPowerPhysicalIndex }
        ::= { hh3cEntityExtPowerTable 1 }

    Hh3cEntityExtPowerEntry ::= SEQUENCE {
        hh3cEntityExtPowerPhysicalIndex
            Integer32,
        hh3cEntityExtNominalPower
            Gauge32,
        hh3cEntityExtCurrentPower
            Gauge32,
        hh3cEntityExtAveragePower
            Integer32,
        hh3cEntityExtPeakPower
            Integer32
     }

    hh3cEntityExtPowerPhysicalIndex OBJECT-TYPE
        SYNTAX Integer32 (1..2147483647)
        MAX-ACCESS accessible-for-notify
        STATUS current
        DESCRIPTION
            "The index of hh3cEntityExtPowerTable.
            This index is identical to entPhysicalIndex in ENTITY-MIB."
        ::= { hh3cEntityExtPowerEntry 1 }

    hh3cEntityExtNominalPower OBJECT-TYPE
        SYNTAX Gauge32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The nominal power of the entity expressed in milliWatts."
        ::= { hh3cEntityExtPowerEntry 2 }

    hh3cEntityExtCurrentPower OBJECT-TYPE
        SYNTAX Gauge32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The measured usage power of the entity expressed in milliWatts."
        ::= { hh3cEntityExtPowerEntry 3 }

    hh3cEntityExtAveragePower OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The average power consumed by the entity expressed in milliWatts.
            Writing a value of zero to this object resets its value to zero.
            Writing any other value to this object has no effect on its value
            and an error is returned."
        ::= { hh3cEntityExtPowerEntry 4 }

    hh3cEntityExtPeakPower OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "The peak power consumed by the entity expressed in milliWatts.
            Writing a value of zero to this object resets its value to zero.
            Writing any other value to this object has no effect on its value
            and an error is returned."
        ::= { hh3cEntityExtPowerEntry 5 }

-- Process Table
    hh3cProcessObjects OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 4 }

    hh3cProcessTable OBJECT-TYPE
        SYNTAX SEQUENCE OF Hh3cProcessEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The Table describes the information about a particular process,
            namely a task."
        ::= { hh3cProcessObjects 1 }

    hh3cProcessEntry OBJECT-TYPE
        SYNTAX Hh3cProcessEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The information about a particular process, namely a task."
        INDEX { hh3cProcessID }
        ::= { hh3cProcessTable 1 }

    Hh3cProcessEntry ::= SEQUENCE {
        hh3cProcessID          Unsigned32,
        hh3cProcessName        DisplayString,
        hh3cProcessUtil5Min    Unsigned32
     }

    hh3cProcessID OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the identifier of process, namely task ID
            in system."
    ::= { hh3cProcessEntry 1 }

    hh3cProcessName OBJECT-TYPE
        SYNTAX          DisplayString(SIZE(1..32))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the process name."
    ::= { hh3cProcessEntry 2 }

    hh3cProcessUtil5Min OBJECT-TYPE
        SYNTAX          Unsigned32(0..100)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object provides a general idea of how busy a process caused
            the processor to be over a 5 minute period.  The ratio is calculated
            by the overall CPU usage caused by the process."
    ::= { hh3cProcessEntry 3 }

    hh3cEntityExtVoltageObjects OBJECT IDENTIFIER ::= { hh3cEntityExtObjects 5 }

    hh3cEntityExtVoltageTable OBJECT-TYPE
        SYNTAX SEQUENCE OF Hh3cEntityExtVoltageEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The table describes the voltage information of the voltage sensor
            entities on the device."
        ::= { hh3cEntityExtVoltageObjects 1 }

    hh3cEntityExtVoltageEntry OBJECT-TYPE
        SYNTAX Hh3cEntityExtVoltageEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "The voltage information of the voltage sensor entity."
        INDEX { hh3cEntityExtPhysicalIndex }
        ::= { hh3cEntityExtVoltageTable 1 }

    Hh3cEntityExtVoltageEntry ::= SEQUENCE {
        hh3cEntityExtCurrentVoltage
            Integer32,
        hh3cEntityExtNominalVoltage
            Integer32,
        hh3cEntityExtVoltageState
            INTEGER,
        hh3cEntityExtVoltageMajorLowThreshold
            Integer32,
        hh3cEntityExtVoltageFatalLowThreshold
            Integer32,
        hh3cEntityExtVoltageMajorHighThreshold
            Integer32,
        hh3cEntityExtVoltageFatalHighThreshold
            Integer32
     }

    hh3cEntityExtCurrentVoltage OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The current voltage in millivolts of the voltage
            sensor entity."
    ::= { hh3cEntityExtVoltageEntry 1 }

    hh3cEntityExtNominalVoltage OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The nominal voltage in millivolts of the voltage
            sensor entity."
    ::= { hh3cEntityExtVoltageEntry 2 }

    hh3cEntityExtVoltageState OBJECT-TYPE
        SYNTAX          INTEGER
        {
             normal   (0),
             low      (1),
             tooLow  (2),
             high     (3),
             tooHigh (4)
        }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The voltage state of the voltage sensor entity."
    ::= { hh3cEntityExtVoltageEntry 3 }

    hh3cEntityExtVoltageMajorLowThreshold OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The low threshold for the voltage sensor entity.

            When the voltage is lower than the threshold, a notification
            will be sent."
    ::= { hh3cEntityExtVoltageEntry 4 }

    hh3cEntityExtVoltageFatalLowThreshold OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The fatal low voltage threshold for the voltage sensor entity.

            When the voltage is lower than the threshold, a notification
            will be sent."
    ::= { hh3cEntityExtVoltageEntry 5 }

    hh3cEntityExtVoltageMajorHighThreshold OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The high threshold for the voltage sensor entity.

            When the voltage is higher than the threshold, a notification
            will be sent."
    ::= { hh3cEntityExtVoltageEntry 6 }

    hh3cEntityExtVoltageFatalHighThreshold OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The fatal high threshold for the voltage sensor entity.

            When the voltage is higher than the threshold, a notification
            will be sent."
    ::= { hh3cEntityExtVoltageEntry 7 }

-- End

    hh3cEntityExtTraps OBJECT IDENTIFIER ::= { hh3cEntityExtend 2 }

    hh3cEntityExtTrapsPrefix OBJECT IDENTIFIER ::= { hh3cEntityExtTraps 0 }
    hh3cEntityExtTrapsInfor OBJECT IDENTIFIER ::= { hh3cEntityExtTraps 1 }

    hh3cEntityExtTemperatureThresholdNotification NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtTemperature,
            hh3cEntityExtTemperatureThreshold,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtTemperatureThresholdNotification
            indicates the temperature exceeded the threshold.
            In this condition, user should check the status and the
            environment of the entity, sometimes it happens because
            of the failure of air-condition."
        ::= { hh3cEntityExtTrapsPrefix 1 }

    hh3cEntityExtVoltageLowThresholdNotification NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtVoltage,
            hh3cEntityExtVoltageLowThreshold,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtVoltageLowThresholdNotification indicates
            the voltage is lower than the threshold.

            If the voltage is lower too much than the entity needs,
            the entity will halt."
        ::= { hh3cEntityExtTrapsPrefix 2 }

    hh3cEntityExtVoltageHighThresholdNotification NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtVoltage,
            hh3cEntityExtVoltageHighThreshold,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtVoltageHighThresholdNotification indicates
            the voltage is higher than the threshold.

            If the voltage is higher too much than the entity needs,
            The entity may be damaged by the high voltage."
        ::= { hh3cEntityExtTrapsPrefix 3 }

    hh3cEntityExtCpuUsageThresholdNotfication NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtCpuUsage,
            hh3cEntityExtCpuUsageThreshold,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight,
            hh3cEntityExtCpuUsageRecoverThreshold,
            hh3cEntityExtFirstTrapTime
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtCpuUsageThresholdNotfication indicates
            the entity is overloaded."
        ::= { hh3cEntityExtTrapsPrefix 4 }

    hh3cEntityExtMemUsageThresholdNotification NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtMemUsage,
            hh3cEntityExtMemUsageThreshold,
            hh3cEntityExtMemSize,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight,
            hh3cEntityExtFirstTrapTime
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtMemUsageThresholdNotification indicates
            the entity is overloaded."
        ::= { hh3cEntityExtTrapsPrefix 5 }

    hh3cEntityExtOperEnabled NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the entity is operable at present."
        ::= { hh3cEntityExtTrapsPrefix 6 }

    hh3cEntityExtOperDisabled NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the entity is not operable at present."
        ::= { hh3cEntityExtTrapsPrefix 7 }

    hh3cEntityExtCriticalTemperatureThresholdNotification NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtTemperature,
            hh3cEntityExtCriticalTemperatureThreshold,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtCriticalTemperatureThresholdNotification
            indicates the temperature exceeds the critical temperature.
            In this condition, user should check the status and the
            environment of the entity, sometimes it happens because
            of the failure of air-condition."
        ::= { hh3cEntityExtTrapsPrefix 8 }

    hh3cEntityExtSFPAlarmOn NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtErrorStatus,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap is generated when the SFP module fails
            or runs abnormally for some particular reason."
        ::= { hh3cEntityExtTrapsPrefix 9 }

    hh3cEntityExtSFPAlarmOff NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtErrorStatus,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap is generated when the SFP module restores to
            normal status."
        ::= { hh3cEntityExtTrapsPrefix 10 }

    hh3cEntityExtSFPPhony NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "This module is NOT sold by authorized manufacturer.
            The normal function of the device or assume the maintenance
            responsibility thereof will NOT be guaranteed.
            The trap is generated periodically after a phony module has been
            found."
        ::= { hh3cEntityExtTrapsPrefix 11 }

    hh3cEntityInsert NOTIFICATION-TYPE
        OBJECTS { entPhysicalDescr, hh3cEntityExtAdminStatus, hh3cEntityExtOperStatus }
        STATUS current
        DESCRIPTION
            "The trap is generated when a removable entity inserting to
            device."
        ::= { hh3cEntityExtTrapsPrefix 12 }

    hh3cEntityRemove NOTIFICATION-TYPE
        OBJECTS { entPhysicalDescr, hh3cEntityExtAdminStatus, hh3cEntityExtOperStatus }
        STATUS current
        DESCRIPTION
            "The trap is generated when a removable entity removing from
            device."
        ::= { hh3cEntityExtTrapsPrefix 13 }

    hh3cEntityExtForcedPowerOff NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the entity is forced to power off."
        ::= { hh3cEntityExtTrapsPrefix 14 }

    hh3cEntityExtForcedPowerOn NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the entity is forced to power on."
        ::= { hh3cEntityExtTrapsPrefix 15 }

    hh3cEntityExtFaultAlarmOn NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtErrorStatus,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap indicates a fault occurs on the specified entity."
        ::= { hh3cEntityExtTrapsPrefix 16 }

    hh3cEntityExtFaultAlarmOff NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtErrorStatus,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "The trap indicates a fault disappears on the specified entity."
        ::= { hh3cEntityExtTrapsPrefix 17 }

    hh3cEntityExtResourceLack NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName
            }
        STATUS current
        DESCRIPTION
            "The trap indicates that a kind of resource is not enough on the
            specified entity."
        ::= { hh3cEntityExtTrapsPrefix 18 }

    hh3cEntityExtResourceEnough NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName
            }
        STATUS current
        DESCRIPTION
            "The trap indicates that the entity recovers from the status of no
            enough resource."
        ::= { hh3cEntityExtTrapsPrefix 19 }

    hh3cEntityExtTemperatureLower NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtTemperature,
            hh3cEntityExtLowerTemperatureThreshold,
            hh3cEntityExtAdminStatus
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the temperature of a specified entity is under
            the lower threshold. In this condition, user should check the
            status and the environment of the entity, sometimes it goes wrong
            for some reason."
        ::= { hh3cEntityExtTrapsPrefix 20 }

    hh3cEntityExtTemperatureTooUp NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtTemperature,
            hh3cEntityExtShutdownTemperatureThreshold,
            hh3cEntityExtAdminStatus
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the temperature of a specified entity exceeded
            the shutdown threshold. In this condition, user should check the
            status and the environment of the entity, sometimes it goes wrong
            for some reason."
        ::= { hh3cEntityExtTrapsPrefix 21 }

    hh3cEntityExtTemperatureNormal NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtTemperature,
            hh3cEntityExtLowerTemperatureThreshold,
            hh3cEntityExtTemperatureThreshold,
            hh3cEntityExtAdminStatus
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the temperature of a specified entity recover
            from abnormal status."
        ::= { hh3cEntityExtTrapsPrefix 22 }

    hh3cEntityExternalAlarmOccur NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName
            }
        STATUS current
        DESCRIPTION
            "The trap is generated when the monitored device connected to the
             specified entity fails."
        ::= { hh3cEntityExtTrapsPrefix 23 }

    hh3cEntityExternalAlarmRecover NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName
            }
        STATUS current
        DESCRIPTION
            "The trap is generated when the failed device connected to the
             specified entity returns to normal."
        ::= { hh3cEntityExtTrapsPrefix 24 }

    hh3cEntityExtCpuUsageThresholdRecover NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtCpuUsage,
            hh3cEntityExtCpuUsageThreshold,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight,
            hh3cEntityExtCpuUsageRecoverThreshold,
            hh3cEntityExtFirstTrapTime
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the CPU usage descends the threshold."
        ::= { hh3cEntityExtTrapsPrefix 25 }

    hh3cEntityExtMemUsageThresholdRecover NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtMemUsage,
            hh3cEntityExtMemUsageThreshold,
            hh3cEntityExtMemSize,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight,
            hh3cEntityExtFirstTrapTime
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the memory usage descends the threshold."
        ::= { hh3cEntityExtTrapsPrefix 26 }

    hh3cEntityExtMemAllocatedFailed NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtTrapDescription
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the memory allocated failed."
        ::= { hh3cEntityExtTrapsPrefix 27 }

    hh3cEntityExtECCParityAlarm NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtECCParityAlarmStatus,
            hh3cEntityExtTrapDescription
            }
        STATUS current
        DESCRIPTION
            "The trap indicates the ECC(Error Correction Code) parity error alarm."
        ::= { hh3cEntityExtTrapsPrefix 28 }

    hh3cEntityExtCritLowerTempThresholdNotification NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtTemperature,
            hh3cEntityExtCriticalLowerTemperatureThreshold
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtCritLowerTempThresholdNotification
            indicates the temperature is lower than the threshold.

            If the temperature is lower too much than the entity needs,
            the entity will halt."
        ::= { hh3cEntityExtTrapsPrefix 29 }

    hh3cEntityExtTemperatureTooLow NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtTemperature,
            hh3cEntityExtShutdownLowerTemperatureThreshold
            }
        STATUS current
        DESCRIPTION
            "The hh3cEntityExtTemperatureTooLow indicates the temperature
            is lower than the threshold.

            If the temperature is lower too much than the entity needs,
            the entity halts now."
        ::= { hh3cEntityExtTrapsPrefix 30 }

    hh3cEntityExtFanDirectionNotPreferred NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName
            }
        STATUS current
        DESCRIPTION
            "This trap indicates the specified fan's direction does not
            accord with preferred. The two parameters indicate the entity
            index and physical name of fan."
        ::= { hh3cEntityExtTrapsPrefix 31 }

    hh3cEntityExtFanDirectionNotAccord NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName
            }
        STATUS current
        DESCRIPTION
            "This trap indicates the direction of fans does not accord
            with each other. The two parameters indicate the parent
            entity of the fans."
        ::= { hh3cEntityExtTrapsPrefix 32 }

    hh3cEntityExtSFPInvalid NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtSFPInvalidInDays
            }
        STATUS current
        DESCRIPTION
            "The transceiver module is not compatible with the interface card.
            The authorized manufacturer therefore shall NOT guarantee
            the normal function of the transceiver.
            The transceiver module will be invalidated in days.
            Please replace it with a compatible one as soon as possible.
            The trap is generated periodically after a phony transceiver module
            has been found."
        ::= { hh3cEntityExtTrapsPrefix 33 }

    hh3cEntityExtSFPInvalidNow NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName
            }
        STATUS current
        DESCRIPTION
            "This transceiver module is not compatible with the interface card.
            The authorized manufacturer therefore shall NOT guarantee
            the normal function of the transceiver.
            The trap is generated after a phony transceiver module
            has been found."
        ::= { hh3cEntityExtTrapsPrefix 34 }

    hh3cEntityExtMemUsageThresholdOverTrap NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtMemUsage,
            hh3cEntityExtMemUsageThreshold,
            hh3cEntityExtMemSizeRev,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "This trap indicates that the memory usage of the entity is
            overloaded.

            This trap is used to replace
            hh3cEntityExtMemUsageThresholdNotification."
        ::= { hh3cEntityExtTrapsPrefix 35 }

    hh3cEntityExtMemUsageThresholdRecoverTrap NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtMemUsage,
            hh3cEntityExtMemUsageThreshold,
            hh3cEntityExtMemSizeRev,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight
            }
        STATUS current
        DESCRIPTION
            "This trap indicates that the memory usage decreased below
            the threshold.

            This trap is used to replace
            hh3cEntityExtMemUsageThresholdRecover."
        ::= { hh3cEntityExtTrapsPrefix 36 }

    hh3cEntityExtVoltageNormal NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtCurrentVoltage,
            hh3cEntityExtNominalVoltage,
            hh3cEntityExtVoltageMajorLowThreshold,
            hh3cEntityExtVoltageMajorHighThreshold
            }
        STATUS current
        DESCRIPTION
            "This trap indicates that the voltage recovers to normal."
        ::= { hh3cEntityExtTrapsPrefix 37 }

    hh3cEntityExtVoltageLower NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtCurrentVoltage,
            hh3cEntityExtNominalVoltage,
            hh3cEntityExtVoltageMajorLowThreshold
            }
        STATUS current
        DESCRIPTION
            "This trap indicates that the voltage is lower than the
            low threshold."
        ::= { hh3cEntityExtTrapsPrefix 38 }

    hh3cEntityExtVoltageTooLow NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtCurrentVoltage,
            hh3cEntityExtNominalVoltage,
            hh3cEntityExtVoltageFatalLowThreshold
            }
        STATUS current
        DESCRIPTION
            "This trap indicates that the voltage is lower than the
            fatal low threshold."
        ::= { hh3cEntityExtTrapsPrefix 39 }

    hh3cEntityExtVoltageHigher NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtCurrentVoltage,
            hh3cEntityExtNominalVoltage,
            hh3cEntityExtVoltageMajorHighThreshold
            }
        STATUS current
        DESCRIPTION
            "This trap indicates that the voltage is higher than the
            high threshold."
        ::= { hh3cEntityExtTrapsPrefix 40 }

    hh3cEntityExtVoltageTooHigh NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtCurrentVoltage,
            hh3cEntityExtNominalVoltage,
            hh3cEntityExtVoltageFatalHighThreshold
            }
        STATUS current
        DESCRIPTION
            "This trap indicates that the voltage is higher than the
            fatal high threshold."
        ::= { hh3cEntityExtTrapsPrefix 41 }

    hh3cEntityExtSFPAlarmOnEx NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight,
            hh3cEntityExtErrorStatus
            }
        STATUS current
        DESCRIPTION
            "The trap is generated when the SFP module fails
            or runs abnormally for some particular reason.
            This trap is used to replace hh3cEntityExtSFPAlarmOn."
        ::= { hh3cEntityExtTrapsPrefix 42 }

    hh3cEntityExtSFPAlarmOffEx NOTIFICATION-TYPE
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            entPhysicalName,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtAlarmLight,
            hh3cEntityExtErrorStatus
            }
        STATUS current
        DESCRIPTION
            "The trap is generated when the SFP module is restored to
            normal status.
            This trap is used to replace hh3cEntityExtSFPAlarmOff."
        ::= { hh3cEntityExtTrapsPrefix 43 }

    hh3cEntityExtTrapDescription OBJECT-TYPE
        SYNTAX      SnmpAdminString (SIZE (0..255))
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "The information of trap."
        ::= { hh3cEntityExtTrapsInfor 1 }

    hh3cEntityExtECCParityAlarmStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                         other(1),
                         l1cache(2),       -- cpu l1 data cache err
                         l2cache(3),       -- cpu l2 data cache err
                         sdram(4),         -- sdram err for cpu
                         mac(5),           -- mac err
                         tcam(6),          -- tcam err
                         ingressbuffer(7), -- IB err
                         egressbuffer(8),  -- EB err
                         lpm(9),           -- lpm err
                         controlmemory(10) -- controlmemory err
                        }
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
               "ECC parity error."
        ::= { hh3cEntityExtTrapsInfor 2 }

    hh3cEntityExtSFPInvalidInDays OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "The days when the transceiver module is still valid,
            but after those days, it will be invalidated."
        ::= { hh3cEntityExtTrapsInfor 3 }

    hh3cEntityExtFirstTrapTime OBJECT-TYPE
        SYNTAX      TimeTicks
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "Represents the first trap time."
        ::= { hh3cEntityExtTrapsInfor 4 }

--  Conformance and Compliance
    hh3cEntityExtConformance OBJECT IDENTIFIER ::= { hh3cEntityExtend 3 }

    hh3cEntityExtCompliances OBJECT IDENTIFIER ::= { hh3cEntityExtConformance 1 }

--  this module
    hh3cEntityExtCompliance MODULE-COMPLIANCE
        STATUS current
        DESCRIPTION
            "The compliance statement for systems supporting this MIB."
        MODULE -- this module
            MANDATORY-GROUPS { hh3cEntityExtGroup, hh3cEntityExtNotificationGroup,
                               hh3cEntityExtManuGroup, hh3cEntityExtPowerGroup }
            OBJECT hh3cEntityExtAdminStatus
                MIN-ACCESS read-only
                DESCRIPTION
                    "Write access is not required."
            OBJECT hh3cEntityExtCpuUsageThreshold
                MIN-ACCESS read-only
                DESCRIPTION
                    "Write access is not required."
            OBJECT hh3cEntityExtMemUsageThreshold
                MIN-ACCESS read-only
                DESCRIPTION
                    "Write access is not required."
            OBJECT hh3cEntityExtTemperatureThreshold
                MIN-ACCESS read-only
                DESCRIPTION
                    "Write access is not required."
            OBJECT hh3cEntityExtVoltageLowThreshold
                MIN-ACCESS read-only
                DESCRIPTION
                    "Write access is not required."
            OBJECT hh3cEntityExtVoltageHighThreshold
                MIN-ACCESS read-only
                DESCRIPTION
                    "Write access is not required."
        ::= { hh3cEntityExtCompliances 1 }

    hh3cEntityExtGroups OBJECT IDENTIFIER ::= { hh3cEntityExtConformance 2 }

    hh3cEntityExtGroup OBJECT-GROUP
        OBJECTS {
            hh3cEntityExtPhysicalIndex,
            hh3cEntityExtAdminStatus,
            hh3cEntityExtOperStatus,
            hh3cEntityExtStandbyStatus,
            hh3cEntityExtAlarmLight,
            hh3cEntityExtCpuUsage,
            hh3cEntityExtCpuUsageThreshold,
            hh3cEntityExtMemUsage,
            hh3cEntityExtMemUsageThreshold,
            hh3cEntityExtMemSize,
            hh3cEntityExtUpTime,
            hh3cEntityExtTemperature,
            hh3cEntityExtTemperatureThreshold,
            hh3cEntityExtVoltage,
            hh3cEntityExtVoltageLowThreshold,
            hh3cEntityExtVoltageHighThreshold,
            hh3cEntityExtCriticalTemperatureThreshold,
            hh3cEntityExtMacAddress,
            hh3cEntityExtErrorStatus,
            hh3cEntityExtCpuMaxUsage,
            hh3cEntityExtLowerTemperatureThreshold,
            hh3cEntityExtShutdownTemperatureThreshold,
            hh3cEntityExtPhyMemSize,
            hh3cEntityExtPhyCpuFrequency,
            hh3cEntityExtFirstUsedDate,
            hh3cEntityExtCpuAvgUsage,
            hh3cEntityExtMemAvgUsage,
            hh3cEntityExtMemType,
            hh3cEntityExtCriticalLowerTemperatureThreshold,
            hh3cEntityExtShutdownLowerTemperatureThreshold,
            hh3cEntityExtCpuUsageRecoverThreshold,
            hh3cEntityExtMemSizeRev,
            hh3cEntityExtCpuUsageIn1Minute,
            hh3cEntityExtCpuUsageIn5Minutes
            }
        STATUS current
        DESCRIPTION
            "Entity Extend group."
        ::= { hh3cEntityExtGroups 1 }

    hh3cEntityExtNotificationGroup NOTIFICATION-GROUP
        NOTIFICATIONS { hh3cEntityExtTemperatureThresholdNotification,
                hh3cEntityExtVoltageLowThresholdNotification,
                hh3cEntityExtVoltageHighThresholdNotification,
                hh3cEntityExtCpuUsageThresholdNotfication,
                hh3cEntityExtMemUsageThresholdNotification,
                hh3cEntityExtOperEnabled,
                hh3cEntityExtOperDisabled,
                hh3cEntityExtCriticalTemperatureThresholdNotification,
                hh3cEntityExtSFPAlarmOn,
                hh3cEntityExtSFPAlarmOff,
                hh3cEntityExtSFPPhony,
                hh3cEntityInsert,
                hh3cEntityRemove,
                hh3cEntityExtForcedPowerOff,
                hh3cEntityExtForcedPowerOn,
                hh3cEntityExtFaultAlarmOn,
                hh3cEntityExtFaultAlarmOff,
                hh3cEntityExtResourceLack,
                hh3cEntityExtResourceEnough,
                hh3cEntityExtTemperatureLower,
                hh3cEntityExtTemperatureTooUp,
                hh3cEntityExtTemperatureNormal,
                hh3cEntityExternalAlarmOccur,
                hh3cEntityExternalAlarmRecover,
                hh3cEntityExtCpuUsageThresholdRecover,
                hh3cEntityExtMemUsageThresholdRecover,
                hh3cEntityExtMemAllocatedFailed,
                hh3cEntityExtECCParityAlarm,
                hh3cEntityExtCritLowerTempThresholdNotification,
                hh3cEntityExtTemperatureTooLow,
                hh3cEntityExtFanDirectionNotPreferred,
                hh3cEntityExtFanDirectionNotAccord,
                hh3cEntityExtSFPInvalid,
                hh3cEntityExtSFPInvalidNow,
                hh3cEntityExtMemUsageThresholdOverTrap,
                hh3cEntityExtMemUsageThresholdRecoverTrap,
                hh3cEntityExtVoltageNormal,
                hh3cEntityExtVoltageTooLow,
                hh3cEntityExtVoltageLower,
                hh3cEntityExtVoltageHigher,
                hh3cEntityExtVoltageTooHigh,
                hh3cEntityExtSFPAlarmOnEx,
                hh3cEntityExtSFPAlarmOffEx
                }
        STATUS current
        DESCRIPTION
            "Entity Extend Notification group."
            ::= { hh3cEntityExtGroups 2 }

    hh3cEntityExtManuGroup OBJECT-GROUP
        OBJECTS {
            hh3cEntityExtManuPhysicalIndex,
            hh3cEntityExtManuSerialNum,
            hh3cEntityExtManuBuildInfo,
            hh3cEntityExtManuBOM,
            hh3cEntityExtMacAddressCount
            }
        STATUS current
        DESCRIPTION
            "Standard Device Manufacture Information group."
        ::= { hh3cEntityExtGroups 3 }

    hh3cEntityExtPowerGroup OBJECT-GROUP
        OBJECTS {
            hh3cEntityExtPowerPhysicalIndex,
            hh3cEntityExtNominalPower,
            hh3cEntityExtCurrentPower,
            hh3cEntityExtAveragePower,
            hh3cEntityExtPeakPower
            }
        STATUS current
        DESCRIPTION
            "Standard Entity Power Information group."
        ::= { hh3cEntityExtGroups 4 }

    END